Replace Electrical Box

- 02.14

How To Replace A Circuit Breaker In A Fuse Box How To Remove A ...
photo src: techwomen.co

Knob-and-tube wiring (sometimes abbreviated K&T) is an early standardized method of electrical wiring in buildings, in common use in North America from about 1880 to the 1930s. It consisted of single-insulated copper conductors run within wall or ceiling cavities, passing through joist and stud drill-holes via protective porcelain insulating tubes, and supported along their length on nailed-down porcelain knob insulators. Where conductors entered a wiring device such as a lamp or switch, or were pulled into a wall, they were protected by flexible cloth insulating sleeving called loom. The first insulation was asphalt-saturated cotton cloth, then rubber became common. Wire splices in such installations were twisted together for good mechanical strength, then soldered and wrapped with rubber insulating tape and friction tape (asphalt saturated cloth), or made inside metal junction boxes.

Knob and tube wiring was eventually displaced from interior wiring systems because of the high cost of installation compared with use of power cables, which combined both power conductors of a circuit in one run (and which later included grounding conductors).

At present, new knob and tube installations are permitted in the US only in a few very specific situations listed in the National Electrical Code, such as certain industrial and agricultural environments.


How To Replace Loose Wobbling Ceiling Fan Wiring Junction Box ...
photo src: www.youtube.com


Maps, Directions, and Place Reviews



Elements

Ceramic knobs were cylindrical and generally nailed directly into the wall studs or floor joists. Most had a circular groove running around their circumference, although some were constructed in two pieces with pass-through grooves on each side of the nail in the middle. A leather washer often cushioned the ceramic, to reduce breakage during installation.

By wrapping electrical wires around the knob, and securing them with tie wires, the knob could be used to securely and permanently anchor the wire. The knobs separated the wire from potentially combustible framework, facilitated changes in direction, and ensured that wires were not subject to excessive tension. Because the wires were suspended in air, they could dissipate heat well.

Ceramic tubes were inserted into holes bored in wall studs or floor joists, and the wires were directed through them. This kept the wires from coming into contact with the wood framing members and from being compressed by the wood as the house settled. Ceramic tubes were sometimes also used when wires crossed over each other, for protection in case the upper wire were to break and fall on the lower conductor.

Ceramic cleats, which were block-shaped pieces, served a purpose similar to that of the knobs. Not all knob and tube installations utilized cleats.

Ceramic bushings protected each wire entering a metal device box, when such an enclosure was used.

Loom, a woven flexible insulating sleeve, was slipped over insulated wire to provide additional protection whenever a wire passed over or under another wire, when a wire entered a metal device enclosure, and in other situations prescribed by code.

Other ceramic pieces would typically be used as a junction point between the wiring system proper, and the more flexible cloth-clad wiring found in light fixtures or other permanent, hard-wired devices. When a generic power outlet was desired, the wiring could run directly into the junction box through a tube of protective loom and a ceramic bushing.

Wiring devices such as light switches, receptacle outlets, and lamp sockets were either surface-mounted, suspended, or flush-mounted within walls and ceilings. Only in the last case were metal boxes always used to enclose the wiring and device.


Replace Electrical Box Video



Unusual wiring layouts

In many older K&T installations, the supply and return wires were routed separately from each other, rather than being located parallel to and near each other. This direct routing method has the advantage of reduced cost by allowing use of the shortest possible lengths of wire, but the major disadvantage is that a detailed building wiring diagram is needed for other electricians to understand multiple interwoven circuits, especially if the wiring is not fully visible throughout its length. By contrast, modern electrical codes now require that all residential wiring connections be made only inside protective enclosures, such as junction boxes, and that all connections must remain accessible for inspection, troubleshooting, repair, or modification.

For example, consider the installation of a light, controlled by two switches in different locations. In modern practice, the supply and return wires both arrive at the first switch, where the supply is connected to one of the two switching wires (hot/red); the return wire is carried inside the same multi-conductor cable to the distant second switch. From there, a supply wire carries power to the light, and a return wire goes back to location of the second switch, and then retraces the path back to the fusebox.

For older K&T installations, the supply and return wires were not necessarily installed as a pair, and did not necessarily have to be near each other at all. From the fusebox, a single supply wire would go to the first switch. From there, it would divide into two switching wires. At the second, remote switch the two wires would come together to be a single supply wire again. Finally this supply wire would be routed from the second switch to the light fixture, and then a single return wire would take the shortest path through the building back to the fusebox. The foregoing is an example of the so-called Carter system wire layout.

In the case of modern North American split-phase power, the supply wires from two opposite single-phase circuit breakers are used to supply 240 V AC for high power devices. In modern circuits, these two wires are grouped together, and for each 240 V device a dedicated circuit is installed, usually with the two circuit breakers ganged together to operate simultaneously.

But with old K&T, a past electrician might have reasoned as follows: "I have a 20 amp circuit on one phase over here, and another 20 amp circuit on an opposite phase over there. Rather than run an entirely new set of wires for this one device, I will just tap off the supply wires of those two circuits and bring them together for this one device." This method of wiring does work and it reduces the amount of wire used, but it makes electrical problems very hard to find and fix, with (possibly undocumented) wires going all over the place within the walls and ceilings, to whatever was the most expedient supply or return wire at the time of installation.

Under the US electrical code, Carter system wiring layouts have now been banned, even for permissible new installations of K&T wiring. However, electricians must be aware of this older system, which is still present in many existing older electrical installations.


Mount Ceiling Fan to Old Junction Box? - Home Improvement Stack ...
photo src: diy.stackexchange.com


Neutral fusing

Another practice that was common (or even required) in some older K&T designs was the installation of separate fuses in both the hot wire and the neutral (return) wire of an electrical circuit. The failure of a neutral fuse would cut off power flow through the affected circuit, but the hot conductor could still remain hot relative to ground, an unexpected and potentially hazardous situation. Because of the presence of a neutral fuse, the neutral conductor could not be relied on to remain near ground potential, and could in fact be at full line potential instead (via transmission of voltage through a switched-on light bulb, for example).

Modern electrical codes generally do not require a neutral fuse. Instead, they explicitly forbid configurations that might break continuity of the neutral conductor, unless all associated hot conductors are also simultaneously disconnected (for example, with ganged or "tied" circuit breakers).


How To Replace A Breaker In A Fuse Box How To Remove A Circuit ...
photo src: techwomen.co


Advantages

In the early 1900s, K&T wiring was less expensive to install than other wiring methods. For several decades, electricians could choose between K&T wiring, conduit, armored cable, and metal junction boxes. The conduit methods were known to be of better quality, but cost significantly more than K&T. In 1909, flexible armored cable cost about twice as much as K&T, and conduit cost about three times the price of K&T. Knob and tube wiring persisted since it allowed owners to wire a building for electricity at lower cost.

Modern wiring methods assume two or more load-carrying conductors will lie very near each other, as for instance in standard NM-2 cable. Since the load-carrying wires are in proximity, when they heat up, the heating is shared across the wires, limiting the overall current load they can support. Since the load-carrying wires in K&T wiring are widely spaced, the wires can carry higher currents than the same conductors in proximity. When installed correctly, the K&T wires are held away from the structural materials by ceramic insulators.

K&T wiring was commonly insulated with cotton cloth and soft rubber, in addition to the porcelain standoffs. Although the actual wire covering may have degraded over the decades, the porcelain standoffs have a nearly unlimited lifespan and will keep any bare wires safely insulated. Today, porcelain standoffs are still commonly used with bare-wire electric fencing for livestock, and such porcelain standoffs carry far higher voltage surges without risk of shorting to ground.

In short, K&T wiring that was installed correctly, and not damaged or incorrectly modified since then, is fairly safe when used within the original current-carrying limits.


Washing machine outlet box | The Home Depot Community
photo src: community.homedepot.com


Disadvantages

Historically, wiring installation requirements were less demanding in the age of knob-and-tube wiring than today. Compared to modern electrical wiring standards, these are the main technical shortcomings of knob-and-tube wiring methods:

  • never included a safety grounding conductor
  • did not confine switching to the hot conductor (the so-called Carter system places electrical loads across the common terminals of a three-way switch pair)
  • permitted the use of in-line splices in walls without a junction box (however, this downside is offset by the strong nature of the soldered and taped junctions used at the time).

Over time, the price of electrician labor grew faster than the cost of materials. This removed the price advantage of K&T methods, especially since they required time-consuming skillful soldering of in-line splices and junctions, and careful hand-wrapping of connections in layers of insulating tape.

Knob-and-tube wiring can be made with high current carrying capacity. However, most existing residential knob-and-tube installations, dating to before 1940, have fewer branch circuits than is desired today. While these installations were adequate for the electrical loads at the time of installation, modern households use a range and intensity of electrical equipment unforeseen at the time. Household power use increased dramatically following World War II, due to the wide availability of new electrical appliances and devices.

Modern home buyers often find that existing K&T systems lack the capacity for today's levels of power use. First-generation wiring systems became susceptible to abuse by homeowners who would replace blown fuses with fuses rated for higher current. This overfusing of the circuits subjects wiring to higher levels of current and risks heat damage or fire.

Knob-and-tube wiring may also be damaged by building renovations. Its cloth and rubber insulation can dry out and turn brittle. It may also be damaged by rodents and careless activities such as hanging objects from wiring running in accessible areas like basements.

Currently, the United States National Electrical Code forbids the use of loose, blown-in, or expanding foam insulation over K&T wiring. This is because K&T is designed to let heat dissipate to the surrounding air. As a result, energy efficiency upgrades that involve insulating previously uninsulated walls usually also require replacement of the wiring in affected homes. However, California, Washington, Nebraska, and Oregon have modified the NEC to conditionally allow insulation around K&T. They did not find a single fire that was attributed to K&T, and permit insulation provided the home first passes inspection by an electrician.

As existing K&T wiring gets older, insurance companies may deny coverage due to a perception of increased risk. Several companies will not write new homeowners policies at all unless all K&T wiring is replaced, or an electrician certifies that the wiring is in good condition. Also, many institutional lenders are unwilling to finance a home with the relatively low-capacity service typical of K&T wiring, unless the electrical service is upgraded. Partial upgrades, where low demand lighting circuits are left intact, may be acceptable to some insurers.

Source of the article : Wikipedia